Driver LED Tridonic LCI 030/700MA 24166314
22,49 €
total
18,29 €
subtotal
In Stock
in stock
pcs.
Manufacturer: Tridonic
VAT: 23,00%
UPC Code: 9006210346502
Symbol: 24166314
Height: 0 cm
Length: 0 cm
Width: 0 cm
Specification
-
VAT:23,00%
-
UPC Code:9006210346502
-
Symbol:24166314
Product Description
TRIDONIC LCI 30 W 700 mA IP20 Power Supply (TEC series) – Compact Fixed Output LED Driver
TRIDONIC constant current LED driver from the TEC series with an output current of 700 mA and a power of 30 W. Universal power supply range 120–240 V AC/DC, high efficiency >80%, thermal and overload protection, protection class II (SELV), IP20 housing. Model according to the data sheet: LCI 030/0700 E020, item no. 24166314.
Key Features
- Constant output current: 700 mA (tolerance ±8%), power up to 30 W.
- Universal power supply: 120–240 V AC (50/60 Hz) / DC; PF > 0.95 (230 V/50 Hz).
- High efficiency: > 80%; quick start? 0.5 s.
- Protections: overheating, overload (auto-restart), short circuit (shutdown + auto-restart).
- Protection class: II, SELV; degree of protection IP20.
- Cable entry/strain relief: strain relief;
- Screw connections.
Electrical and operating data
- Rated supply voltage: 120–240 V; AC range: 108–264 V; DC range: 120–240 V.
- Maximum power consumption: 35 W; mains current (230 V/50 Hz): 0.16 A.
- Output voltage range: 21–43 V; max. no-load voltage: 48 V.
- Output current ripple: ±43%; repetitive/non-repetitive peak current: 1100 mA.
- Backup time during power failure: 10 ms.
- Ambient temperature (ta): -25…+50 °C (for 50,000 h: up to +40 °C); tc max.: 75 °C.
- Lifespan up to: 50,000 h; glow threshold: 850 °C (EN 60695-2-11).
Dimensions and installation
- Dimensions (LxWxH): 165 × 43 × 30 mm; hole spacing: 142 mm.
- Cables: input 0.5–1.5 mm2, output 1.0–2.5 mm2; stripping length: 7.5–8.5 mm.
- Max. LED cable length: 2 m; recommended distance between power cables and LED cables: 5–10 cm.
- Maximum mounting torque: 0.5 Nm (M4).
Compliance and standards
- Standards: EN 55015, EN 61000-3-2, EN 61000-3-3, EN 61347-1, EN 61347-2-13, EN 61547, EN 62384.
- Installation class: Class II device; In Class I luminaires, additional measures are required (according to the manufacturer's guidelines).
- Do not connect/disconnect LED modules on the secondary side (SEC).
- If the output voltage is exceeded, automatic shutdown occurs and restart occurs after the cause is removed.
- Protect cables from ground short circuits/sharp edges; keep them as short as possible to reduce EMI.
- Insulation strength tests in luminaires should be performed in accordance with IEC 60598-1 Annex Q (500 V DC/1 s).
Installation / Safety Instructions